Skip to content

Browser keywords in applications

Electron and VSCode contain the Browser keywords that apply to applications. They work on an application’s windows as they do on the pages of a web browser. This guide lists, for each group of keywords, what works, which keywords the libraries hide and why, which keywords fail, and where Electron behaves differently.

The results come from Electron 44.7 and VS Code 1.141 under Xvfb, with Browser on Playwright 1.63. The acceptance tests in packages/electron/atest/browser_keywords/ check the groups of the overview on an Electron application, except the row “Other keywords”, and every keyword that this guide lists as failing.

  • One browser, one context. Start Electron Application and Start VS Code make the application a browser with one context. Each window of the application is a page of that context, and so are its <webview>s and WebContentsViews.
  • The application creates its pages. The libraries hide New Page, New Context and the other keywords for browsers and contexts, and offer keywords for applications instead, see Compared with the Browser library.
  • Settings mean a restart. Options such as the color scheme or the locale apply from the start, see launch options. Another value means starting the application again.
  • The main process is outside the pages. Native dialogs, menus and the tray belong to the main process, which Browser keywords do not reach. Evaluate In Main Process runs code there, see the main process.
Group Status Notes
Locators Works CSS, XPath, text, id=, data-testid=, role=, Get Element By and chains with >>, also through shadow roots and into iframes with >>>. See Locators.
Reading content Works Get Text, Get Attribute, Get Property, Get Style, the table keywords, Evaluate JavaScript, Get Console Log and Get Page Errors. Get Aria Snapshot lists roles and names, which helps to find locators.
Input Works Typing, Fill Secret, checkboxes and selects, file uploads with Upload File By Selector and Promise To Upload File, keyboard, mouse, Drag And Drop and scrolling. Shortcuts with ControlOrMeta work on every platform, but they reach only the page, not the application’s menu, see Shortcuts and menus.
Waiting and navigation Works Wait For Elements State, Wait For Condition, Wait For Function, Wait For Request, Wait For Response, promises with Promise To and Wait For, Http, Go To, Go Back and Go Forward, and the timeouts and retries of Set Browser Timeout and Set Retry Assertions For.
Context state Works Cookies, local and session storage, Grant Permissions, Set Geolocation, Set Offline, Emulate Media, Set Viewport Size and the clock keywords Set Time, Pause At and Advance Clock. Get Viewport Size returns None until Set Viewport Size emulates a size; the window keeps its own size. Save Storage State works only while every http and https origin that the application has visited is open in a window, and it leaves out the storage of file:// pages. Set Storage State is hidden.
Dialogs Works alert and confirm with Handle Future Dialogs, Wait For Alert and Wait For Alerts. Without a handler, Playwright dismisses them. Electron has no prompt(), see Behaviour of Electron. Both kinds of handler on the same page crash Browser’s Node process, and so does a beforeunload handler, see Known crashes. Native dialogs need the main process.
Downloads Works Promise To Wait For Download after a click, also with wait_for_finished=False and Get Download State, and Download from a page loaded from a URL. Cancel Download cancels a running download. The libraries tell Browser that the application accepts downloads, as Electron does.
Pages and windows Works Windows that the application opens later: Switch Window with their title. <webview>s and WebContentsViews are pages too, but select them by page id, see Pages and windows. A window that the application closes leaves Get Page Ids. Close Page closes windows and WebContentsViews, but waits forever on a <webview>. On the last window, it ends most applications, through their window-all-closed handler.
Screenshots, recordings and coverage Works Take Screenshot of the window or an element; screenshots have the window’s size. Videos, traces and HAR files come from record_video, tracing and record_har of Start Electron Application, see Videos and slow motion and Traces and HAR files. Start Coverage, Highlight Elements, Add Style Tag and presenter mode work. Playwright has no slowMo for Electron; presenter mode slows a test down instead.
Applications Own keywords Switch Electron Application, Get Electron Application Ids and Get Electron Application Catalog replace Browser’s keywords for browsers and contexts, see Compared with the Browser library.
Other keywords Works From the audit: locator handlers, WebAuthn credentials (Create Credential and the related keywords), Register Keyword To Run On Failure, Show Keyword Banner and Set Strict Mode.

Electron and VSCode hide the Browser keywords for browsers and contexts, because an application is one browser with one context, and the keywords that cannot work on an application. They offer these keywords instead:

Browser keyword In Electron and VSCode Why
New Browser, New Persistent Context, Open Browser Start Electron Application, Start VS Code A test starts an application.
Close Browser, Close Context Close Electron Application, Close VS Code The application ends with its only context.
Switch Browser Switch Electron Application Several applications can be open at once.
Get Browser Ids Get Electron Application Ids It returns the ids of the open applications.
Get Browser Catalog Get Electron Application Catalog It leaves out the context level.
New Context, Switch Context, Get Context Ids – An application has exactly one context.
New Page – The application opens its windows itself.
Launch Browser Server, Close Browser Server, Connect To Browser – For browsers only.
Get Device, Get Devices – Devices are options for New Context.
Crawl Site – It opens pages of its own.
Set Storage State – It needs a page of its own to write the storage.
Tap – Touch input is not enabled for applications.
Save Page As Pdf – Electron, and with it VS Code, does not provide Chromium’s PDF printing over the DevTools protocol.

A test that needs a web browser as well imports the Browser library beside Electron or VSCode. Keywords that both libraries have then need the library name:

*** Settings ***
Library Electron
Library Browser
*** Test Cases ***
Web Page Beside An Application
Start Electron Application /opt/my-app/my-app
Browser.New Browser chromium headless=True
Browser.New Page https://example.com/
Electron.Get Title == My App

These visible keywords fail on an application under some conditions. The acceptance tests expect the error, so an upgrade that lifts the limitation is noticed.

Keyword Error Cause
Save Storage State Protocol error (Target.createTarget): Not supported Only when an http or https origin that the application has visited is no longer open in a window: reading its storage then needs a page of its own, which an application cannot open.

Selectors behave as in a web browser. Some details:

  • Shadow roots: CSS, id= and text= find elements in open shadow roots. css:light=, id:light=, text:light= and XPath do not.
  • Iframes: >>> reaches into iframes, for example id=frame >>> id=in-frame.
  • aria-ref=: it finds elements by the references in Get Aria Snapshot <selector> mode=ai, such as aria-ref=e5. The references change with every snapshot, so they help to explore an application, not to write tests.
  • _react= and _vue=: Playwright 1.63 still accepts them, but they fail with “Cannot read properties of undefined (reading ‘queryAll’)”.
  • Your own selector engine: a JavaScript extension can register one with Playwright’s selectors.register. It applies to pages that load after the registration, so register it before the application starts, or Reload the windows that are already open.
async function registerTagEngine(playwright) {
await playwright.selectors.register('tag', () => ({
query: (root, selector) => root.querySelector(selector),
queryAll: (root, selector) => Array.from(root.querySelectorAll(selector)),
}));
}
exports.__esModule = true;
exports.registerTagEngine = registerTagEngine;
*** Settings ***
Library Electron jsextension=${CURDIR}/selector_engine.js
*** Test Cases ***
Find By Tag Name
Register Tag Engine
Start Electron Application /opt/my-app/my-app
Get Text tag=h1 == My App

Every window of the application is a page, and so is every <webview> and every WebContentsView. The window keywords know which pages are windows: Get Window Ids and Get Window Titles list only the windows, and Switch Window switches only to them. They take a window by the title that it shows, title=Settings, by a regular expression for that title in the form of Browser’s text= selector, title=/^Settings/i, or by its id from Get Window Ids, which is valid while the application runs and unique only within it.

Switch to a window that the application opens by its title. Switch Window waits until a window shows it:

Click text=Settings
${previous} = Switch Window title=Settings
Click text=Save
Switch Window ${previous}

Switch Window NEW and Switch Page NEW take the newest page if it is newer than the active page. That can be a <webview> or WebContentsView that loaded after the new window, which Switch Window refuses, or, after a switch back to an older window, a page that was open before. A title has neither problem. Switch Window finds the page of a window through the title of that page, so a window whose page has no title, or shares its title with another page, is switched to with its page id.

<webview>s and WebContentsViews are selected with Switch Page and their page id, which Get Electron Application Catalog lists with their titles. A keyword that switches to the page with a given title:

*** Keywords ***
Switch To Page With Title
[Arguments] ${title}
${catalog} = Get Electron Application Catalog
FOR ${application} IN @{catalog}
FOR ${page} IN @{application}[pages]
IF $application["active"] and $page["title"] == $title
Switch Page ${page}[id]
RETURN
END
END
END
Fail No page with the title '${title}'.
  • >>> and <webview>: a <webview> is not an iframe, so >>> does not reach into it; it fails with <iframe> was expected. Switch to the <webview>’s page instead.

  • Closing a <webview>: Close Page waits forever on a <webview>’s page, because the <webview> element in its host page keeps it. Remove the element instead; its page then goes away:

    Evaluate JavaScript id=guest (element) => element.remove()

    Close Page on a WebContentsView’s page closes it and removes the view from its window.

  • An application that quits by itself stays in Browser’s catalog with an empty context. Keywords then fail with “No page open.” until Close Electron Application, which also passes for an application that has already quit.

  • Color scheme: by default, the application decides its color scheme. color_scheme of Start Electron Application sets one, see launch options.
  • Window size: a window has the size that the application gives it; there is no emulated viewport, so Get Viewport Size returns None. Set Window Size sizes the window and Get Window Size returns its size, which its page, its screenshots and its video have. Set Viewport Size emulates a viewport inside the page.
  • Maximising and minimising: Maximize Window, Minimize Window and Restore Window need a window manager, such as Openbox, which the display profiles start, see CI and the Linux display. On plain Xvfb without one, maximising and minimising fail after the timeout, while Set Window Size works. Some Wayland desktops, such as niri, cannot minimise windows.
  • Minimised windows draw nothing, so Browser keywords on their pages wait until their timeout. Call Restore Window before acting on such a window again.
  • Locale and time zone: they follow the system. locale and timezone_id set them for the windows; --lang in args and TZ in env set them for the main process.
  • User data: Electron keeps cookies, local storage and other data of an application in its user-data folder, on Linux ~/.config/<name>, on Windows %APPDATA%\<name> and on macOS ~/Library/Application Support/<name>, so they last from one run to the next. args=--user-data-dir=<folder> with a new, empty folder starts the application without them, unless it sets the folder itself with app.setPath.
  • prompt(): Electron does not implement it. A page’s call fails with “prompt() is not supported.”, so prompt_input of Handle Future Dialogs never applies.
  • Native dialogs: file dialogs and message boxes are not part of a page. Replace them in the main process, see the main process.

Keyboard keywords send keys to the page. The accelerators of the application’s menu and before-input-event handlers in the main process do not see them, so a shortcut that only the menu handles does nothing. Click the menu item in the main process instead. getMenuItemById finds items that have an id in the application’s menu template:

Evaluate In Main Process ({ Menu }) => Menu.getApplicationMenu().getMenuItemById('open-file').click()

Two problems end Browser’s Node process, and with it every later test of the run. They come from Playwright and Browser, not from these libraries.

  • A beforeunload handler. In Electron, a beforeunload handler that returns a value cancels leaving or closing the page without asking; Electron recommends this to keep a window open. Playwright still sees a dialog, fails to dismiss it, and Browser’s Node process exits. Go To to another page, Close Page runBeforeUnload=True, Close Electron Application and Browser’s automatic closing are affected. Remove the handler before such a step:

    Evaluate JavaScript ${None} () => { window.onbeforeunload = null; }
    Close Electron Application

    A handler added with addEventListener cannot be removed like this. The application then needs a way to switch it off for tests.

  • Handle Future Dialogs and Wait For Alert on the same page. Both accept the same dialog, the second one fails, and the Node process exits. This happens in a web browser too, but an application’s window stays the same page across tests, so a handler from an earlier test is still active. Use one of the two per page, or start the application in each test.